Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(1): e51616, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38313965

RESUMO

Pectoralis major (PM) tendon ruptures are rare. Typically, they are caused by eccentric contractions from weight lifting. Due to the rarity of pectoralis major tendon ruptures, clinicians might misdiagnose this condition. We report a 16-year-old male with a right pectoralis major tendon rupture and an avulsion fracture after falling on a grass field playing soccer. He was initially misdiagnosed with biceps tendonitis, which highlights the importance of including pectoralis major tendon ruptures in one's differential diagnoses.

2.
Am J Perinatol ; 38(S 01): e347-e350, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32446260

RESUMO

OBJECTIVE: The aim of this study was to estimate if preterm premature rupture of membranes in women with cerclage is due to the cerclage itself or rather the underlying risk factors for preterm birth in this population. STUDY DESIGN: This was a retrospective cohort study of singleton pregnancies who underwent Shirodkar cerclage by a single maternal-fetal medicine practice between 2005 and 2019. The control group was an equal number of randomly selected women with a singleton gestation who had a prior preterm birth and were treated with 17-OH-progesterone but no cerclage. Patients with major uterine anomalies or fetal anomalies were excluded. The primary outcome was preterm premature rupture of membranes prior to 34 weeks. Chi-square and logistic regression were used. RESULTS: A total of 350 women with cerclage (154 [44%] history-indicated, 137 [39%] ultrasound-indicated, and 59 [17%] exam-indicated) and 350 controls were included. Preterm premature rupture of membranes prior to 34 weeks did not differ between the groups (8.9% in cerclage vs. 6.0% in controls, p = 0.149, adjusted odds ratio 0.62, 95% confidence interval: 0.24-1.64) nor between the different cerclage indications (9.1% of history-indicated, 7.3% of ultrasound-indicated, and 11.9% of exam-indicated, p = 0.582). This study had 80% power with an α error of 0.05 to detect an increase in preterm premature rupture of membranes prior to 34 weeks from 6.0% in the control group to 12.0% in the cerclage group. CONCLUSION: Cerclage does not increase the risk of preterm premature rupture of membranes prior to 34 weeks compared with other women at increased risk of preterm birth. The observed association between cerclage and preterm premature rupture of membranes is likely due to underlying risk factors and not the cerclage itself. The risk of preterm premature rupture of membranes prior to 34 weeks in women with cerclage is 10% or less and does not appear to differ based on cerclage indication. KEY POINTS: · Cerclage does not increase the risk of PPROM.. · Risk of PPROM with cerclage is approximately 10%.. · Risk does not appear to vary by indication..


Assuntos
Cerclagem Cervical , Ruptura Prematura de Membranas Fetais/cirurgia , Trabalho de Parto Prematuro/epidemiologia , Trabalho de Parto Prematuro/prevenção & controle , Adulto , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Modelos Logísticos , Gravidez , Complicações na Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Fatores de Risco , Ultrassonografia de Intervenção
3.
Trans R Soc Trop Med Hyg ; 113(11): 678-684, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31294807

RESUMO

BACKGROUND: Zika virus (ZIKV) is believed to be endemic in Southeast Asia. However, there have been few Zika cases reported to date in Malaysia, which could be due to high pre-existing levels of population immunity. METHODS: To determine Zika virus (ZIKV) seroprevalence in Kuala Lumpur, Malaysia, 1085 serum samples from 2012, 2014-2015 and 2017 were screened for anti-ZIKV antibodies using a ZIKV NS1 blockade-of-binding assay. Reactive samples were confirmed using neutralization assays against ZIKV and the four dengue virus (DENV) serotypes. A sample was possible ZIKV seropositive with a ZIKV 50% neutralization (NT50) titre ≥20. A sample was probable ZIKV seropositive if, in addition, all DENV NT50 titres were <20 or the ZIKV NT50 titre was >4-fold greater than the highest DENV NT50 titre. RESULTS: We found low rates of possible ZIKV seropositivity (3.3% [95% confidence interval {CI} 2.4 to 4.6]) and probable ZIKV seropositivity (0.6% [95% CI 0.3 to 1.4]). Possible ZIKV seropositivity was independently associated with increasing age (odds ratio [OR] 1.04 [95% CI 1.02 to 1.06], p<0.0001) and male gender (OR 3.5 [95% CI 1.5 to 8.6], p=0.005). CONCLUSIONS: The low ZIKV seroprevalence rate, a proxy for population immunity, does not explain the low incidence of Zika in dengue-hyperendemic Kuala Lumpur. Other factors, such as the possible protective effects of pre-existing flavivirus antibodies or reduced transmission by local mosquito vectors, should be explored. Kuala Lumpur is at high risk of a large-scale Zika epidemic.


Assuntos
Anticorpos Antivirais/sangue , Vírus da Dengue/imunologia , Dengue/epidemiologia , Dengue/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Malásia/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Soroepidemiológicos , Adulto Jovem
4.
Orthop J Sports Med ; 7(6): 2325967119848667, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31218236

RESUMO

BACKGROUND: Previous studies have aimed to biomechanically improve the transosseous tunnel technique of rotator cuff repair. However, no previous work has addressed tunnel inclination at the time of surgery as an influence on the strength of the repair construct. HYPOTHESIS: We hypothesized that the tunnel angle and entry point would influence the biomechanical strength of the transosseous tunnel in rotator cuff repair. Additionally, we investigated how tunnel length and bone quality affect the strength of the repair construct. STUDY DESIGN: Controlled laboratory study. METHODS: Mechanical testing was performed on 10 cadaveric humeri. Variations in the bone tunnel angle were imposed in the supraspinatus footprint to create lateral tunnels with inclinations of 30°, 45°, and 90° relative to the longitudinal axis of the humeral shaft. A closed loop of suture was passed through the bone tunnel, and cyclic loading was applied until failure of the construct. Load to failure and distance between entry points were the dependent variables. Analysis of variance, post hoc paired t tests, and the Bonferroni correction were used to analyze the relationship between the tunnel angle and failure load. The Pearson correlation coefficient was then used to evaluate the correlation of the distance between entry points to the ultimate failure load, and t tests were used to compare failure loads between healthy and osteoporotic bone. RESULTS: Tunnels drilled perpendicularly to the longitudinal axis (90°) achieved the highest mean failure load (167.51 ± 48.35 N). However, there were no significant differences in the failure load among the 3 tested inclinations. Tunnels drilled perpendicularly to the longitudinal axis (90°) measured 13.86 ± 1.35 mm between entry points and were significantly longer (P = .03) than the tunnels drilled at 30° and 45°. We found no correlation of the distance between entry points and the ultimate failure load. Within the scope of this study, we could not identify a significant effect of bone quality on failure load. CONCLUSION: The tunnel angle does not influence the strength of the bone-suture interface in the transosseous rotator cuff repair construct. CLINICAL RELEVANCE: The transosseous technique has gained popularity in recent years, given its arthroscopic use. These findings suggest that surgeons should not focus on the tunnel angle as they seek to maximize repair strength.

5.
Am J Orthop (Belle Mead NJ) ; 45(3): E114-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26991576

RESUMO

In locking plate osteosynthesis, proper surgical technique is crucial in reducing potential pitfalls, and use of a torque limiter makes it possible to control insertion torque. We conducted a study of the ways in which different techniques can alter the accuracy of torque limiters. We tested 22 torque limiters (1.5 Nm) for accuracy using hand and power tools under different rotational scenarios: hand power at low and high velocity and drill power at low and high velocity. We recorded the maximum torque reached after each torque-limiting event. Use of torque limiters under hand power at low velocity and high velocity resulted in significantly (P < .0001) different mean (SD) measurements: 1.49 (0.15) Nm and 3.73 (0.79) Nm. Use under drill power at controlled low velocity and at high velocity also resulted in significantly (P < .0001) different mean (SD) measurements: 1.47 (0.14) Nm and 5.37 (0.90) Nm. Maximum single measurement obtained was 9.0 Nm using drill power at high velocity. Locking screw insertion with improper technique may result in higher than expected torque and subsequent complications. For torque limiters, the most reliable technique involves hand power at slow velocity or drill power with careful control of insertion speed until 1 torque-limiting event occurs.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Erros Médicos , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Humanos , Torque
6.
J Pediatr Orthop B ; 21(6): 587-91, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22568965

RESUMO

UNLABELLED: Child abuse is a significant problem encountered by orthopedic surgeons in the USA. Fractures are the second most common presentation of physical abuse. In this case report, we present a 5-month-old male infant who initially presented with acute hip pain secondary to a femoral neck fracture as a result of abuse. The patient was taken to the operating room for open reduction and pinning of the femoral neck fracture. Further investigation found evidence of fractures of the bilateral femur and fibula at various stages of healing. To our knowledge, a femoral neck fracture in a nonambulatory infant resulting from abuse has not been reported previously. Physicians treating these injuries should consider child abuse in their differential diagnosis when presented with this clinical scenario. LEVEL OF EVIDENCE: Level IV.


Assuntos
Maus-Tratos Infantis/diagnóstico , Vítimas de Crime , Fraturas do Colo Femoral/diagnóstico , Medicina Legal , Pinos Ortopédicos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fíbula/diagnóstico por imagem , Fíbula/lesões , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Humanos , Lactente , Masculino , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...